Sealing
35
10.02.07 Opening / closing the feed rollers
The feed rollers can be opened and closed with this key.
If the material between the closing rollers is thicker than 8
mm, a safety
shutdown is activated that immediately opens the rollers again. The purpose of
this safety shutdown is to prevent the operator's hand becoming trapped.
On the one hand, it reacts to force exerted on the Sonotrode or to the actuation
of the safety switch on the column.
10.02.08 Starting the sealing process manually
The sealing process can be started manually or an interrupted sealing process can be
continued again with the start key. This key works in parallel to the pedal.
The key appears only when the rollers are closed.
It does not appear in dynamic operating modes.
10.02.09 Interrupting the sealing process
The current sealing process can be interrupted with this key. The key works in parallel to the
pedal.
The key appears only after the start of the sealing process.
10.02.10 Manually turning the rollers backwards
The drive rollers are started in reverse by pressing the ā manually turn the rollers backwards
ā key in stop mode. They run as long as the key remains pressed. The rollers stop if the key
is released. An activated motorised puller also moves with them.
A function is available in input mode to test the movement of the rollers in both
directions (rollers forwards-backwards), see chapter 11 Input
10.02.11 Input
This function is used to call up the input menu, see chapter 11 Input