Sealing
44
All other functions work as with manual welding and can be read there.
As already explained in the clear view of dynamic welding, the ultrasonic parameters and the
speed are calculated and connected from the pedal position during welding operations. The
other parameters remain at the set values.
The relative pedal position is shown with a dynamic display (slider).
If the pedal is released before the minimum position (Pos1), a stop is triggered.
In the event that work frequently needs to be done at the minimum limits and an unintended stop
is not desired, a switch-off can prevented with the parameter Dynstop = 1.
The machine continues with the minimum parameters. If you want to stop, briefly press the pedal
in reverse. Alternatively, the stop key could be pressed. If the pedal remains depressed in reverse,
the machine executes a stop in the normal way with the rollers opening.