Input
61
Back up and read back sealing parameters on SD card
This function can be used to back up sealing parameter sets P1..P50 on the SD card and
read them from the SD card. All 50 parameter sets are always backed up or read back all at
once in packages. This is useful because of the links between the parameter sets for pro-
grammed welding.
Up to 30 of these packages can be stored on the SD card (file names 01.PAK to 30.PAK in
the folder P8311 on the SD card).
An information text. which can be displayed later, can be assigned to the package currently
in the memory before it is saved. The default information text is 8303.
Select a free package on the SD card. An LED next to the package number (5) marks the selection.
This key is used to then write the sealing parameter sets in the package 05.PAK on the
SD card
If an existing packaged is marked,
it can be loaded into the memory with the "LOAD" key.
The "DEL" key deletes a selected package on the SD card.