8 - 4
Installation and commissioning
8.02 Commissioning
Before the machine is
commissioned, stopper 1
must
be removed!
● Clean the machine thoroughly and then
check the oil level (see Chapter 12 Care
and Maintenance).
● Check the machine, in particular the
electrical leads, for any damage.
● Have specialists check, whether the
machine can be operated with the
available mains connection.
If there are any irregularities,
do not operate the machine
under any circumstances!
The machine may only be connected to a grounded socket.
● When the machine is running, the balance wheel must turn towards the operator. If
this is not the case, have the machine converted by specialist personnel, see Motor
Service Manual.
● Connect the machine to the compressed air system. The manometer must display a
pressure of 6 bar.
If necessary, set to the correct value (see Chapter 12.04 Checking/
regulating air pressure).
8.03 Switching the machine on/off
● Switch the machine on or off, see Chapter 7.01 On/off switch.
● Carry out a test run.
Fig. 8 - 06
1