13 - 37
Adjustment
24V = 4% ED
49-091
49-090
13.06.04 Engaging solenoid
Requirement
When the needle bar is positioned 1.8 mm after the b.d.c and the engaging solenoid is
actuated, the distance between the engaging lever 1 and the pawl 2 should be between
0.2 and 0.3 mm.
Fig. 13 - 36
4
3
2
1
0.2 -
0.3 mm
● Position the needle bar 1.8 mm after b.d.c
● Manipulate engaging lever 1 until pawl 2 engages.
● Push magneto inductor into the magnet housing 3 as far as possiblt and move magnet
housing 3 (screw 4) together with the magneto inductor in accordance with the
requirement.
2