Figure 11-6. Testing Rectifiers (Negative)
NOTE
Any tools called out by a “C” or “SP” number in this section may be
purchased from:
Miller Special Tools
A Division of Utica Tool Company, Inc.
32612 Park Lane
Garden City, Michigan 48135 Phone: (313) 522-6717
11-12. TESTING RECTIFIERS (NEGATIVE). To test the negative case rectifiers in the end shield, connect
the alligator clip of tool C-3829 to the end shield.
Touch the test prod to the bare wire of the rectifier leads at the rectifiers in the end shield. The meter will
indicate the condition of the rectifier.
The test indications are the same for the negative case rectifiers in the end shield as they are for the
positive case rectifiers in the heat sink. However, the meter will read at the opposite end of the scale.
NOTE
If all three of the negative rectifiers read low, before condemning the
rectifiers, test for a grounded stator. A grounded stator will cause the
negative rectifiers (in the end shield) to read low.
Revised: 2/13/89
2G23
CHEROKEE ARROW III SERVICE MANUAL
ELECTRICAL SYSTEM

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Piper ARROW III and is the answer not in the manual?

Piper ARROW III Specifications

General IconGeneral
BrandPiper
ModelARROW III
CategoryAircrafts
LanguageEnglish

Related product manuals