TABLE XIV-IV. TROUBLESHOOTING CHART (AIR CONDITIONER) (CONT)
Excessively noisy Electrical
system. (cont)
Compressor noisy. Check mounting and repair;
remove compressor for
service or replacement,
14-18.
Compressor oil level Fill with correct amount
low. of specified oil, 14-21.
Refrigeration
Excessive charge in Discharge excess freon until
system. high pressure gauge drops
within specifications.
Low charge in system. Check system for leaks;
charge system, 14-9 and
14-14.
Excessive moisture in Replace dehydrator, purge,
system. evacuate, and charge system,
14-32, 14-13 and 14-14.
Trouble Cause Remedy
Revised: 2/13/89
CHEROKEE ARROW III SERVICE MANUAL