40
3. Perform the Blade Speed Test.
• If the Blade Speed is within spec but the Strobe Exposure Test reading remains
out of spec, replace the exposure flex and retest.
• If the Blade Speed Test reading is not within spec, perform the Blade Speed
Adjustment. If the Blade Speed Adjustment does not correct Blade Speed,
repair the Shutter Assembly and retest.
Excessive Battery Drain
If battery drain is excessive, perform the Strobe Integrated Current Test. If this reading
is out of spec, replace the strobe board.
Long Strobe Recharge Time
If the Strobe takes too long to recharge, perform the Strobe Charge Time Test. If the
reading is out of spec, replace the strobe board.