54
4. Put the Test Top Cover in place and retest the camera. Readjust the IR Strobe
Exposure Calibration Slide if necessary, using the Test Top Cover.
5. When the Strobe Exposure Test reading is within specification, replace the Test Top
Cover with the camera’s own Top Cover.
Note: If adjusting the IR Calibration Slide fails to bring the Strobe Exposure Test
reading within specification, refer to steps 4 and 5 of the Strobe Exposure
(Graywall) Test.