URM18PH392 Rev A. May 2020 Page 65 of 86
6. BIT ERRORS
This section explains the Built-In Test (BIT) error codes that the VIPER may return in response to the BIT
RESULTS command or in response to any other command if the tracker cannot operate with the reported error
condition.
Note: These error codes indicate a malfunction in VIPER™ system hardware or
firmware, or in a system component that may result in inaccurate measurements.
Code
Displayed Message
Definition
Actions to Take
00
No Error
System startup and self-test success.
01
SENSOR Error
A problem with a Sensor has been
detected.
Try a different Sensor to see if
the error is cleared.
Contact Polhemus Technical
Support.
02
SENSOR PORT Error
A problem with an SEU Sensor PORT has
been detected.
Move Sensor to a different port
to see if the error clears.
Contact Polhemus Technical
Support.
03
SOURCE Error
A problem with a Source and/or SEU
Source PORT has been detected.
Try a different Source.
Try a different Source Port.
Contact Polhemus Technical
Support.
04
SEU Error
A problem with SEU hardware or
firmware has been detected.
Contact Polhemus Technical
Support.
05
Duplicate Source
Frequencies
Two or more Sources operating at the
same EM frequency are plugged into the
SEU.
Unplug the duplicate frequency
Source(s).
Replace with a Source of a
different frequency.
Power-cycle VIPER™ or Soft
Reset.