Device Settings
28
480 Hz at –18 dBm and 620 Hz at –18 dBm
The expiration time is exactly 10 seconds. It has only one cadence segment, which has tone active 0.5
second and tone inactive 0.5 second.
Prompt Tone
PROMPT, "480-16;10"
Prompt tone is generated from a single frequency component:
480 Hz at
–16 dBm. The expiration time is exactly 10 seconds. It has only one cadence segment, which has
tone infinite active time.
SIT Tone
SIT_1, "985-16,1428-16,1777-16;20;(1/.380+0,2/.380+0,4/.380+0,0/0+4)"
Special information tone (SIT) is generated from a set of frequency components:
● First frequency: 985 Hz at
–16 dBm
● Second frequency: 1428 Hz at
–16 dBm
● Third frequency: 1777 Hz at
–16 dBm
The expiration time is exactly 20 seconds. It has only one cadence segment, which includes four on-off
sections. The segment has infinite repeating time:
● The first on-off section: generated by the first frequency component, and it has 0.38 tone second
active time and 0 inactive time.
● The second on-off section: generated by the second frequency component, and it has 0.38 tone
second active time and 0 inactive time.
● The third on-off section: generated by the third frequency component, and it has 0.38 tone second
active time and 0 inactive time.
● The fourth on-off section: only generate silence since no frequency component is specified. It has
tone 0 second active time and 4 seconds inactive time.
Stutter Tone
STUTTER, "350-18,440-18;20;.2(.1+.1);()"
Stutter dial tone is generated from a mixture of two frequency components:
350 Hz at
–18 dBm and 440 Hz at –18 dBm. The expiration time for the entire tone is exactly 20 seconds. It
has two cadence segments.
● The first segment includes only one on-off section, on 0.1 second and off 0.1 second, and on-off
repeats for 2 seconds.
● The second segment includes one on-off section, and has infinite repeating time and infinite tone
active time, and plays until the entire tone duration has elapsed.
For more information on Tone Profile A & B parameters, see the Tone Profile A & B Parameter Guide
table
in the Parameter Reference
section.
For more information on call waiting parameters, see the Tone Profile A & B Parameter Guide
table in the
Parameter Reference