System Configuration Flags
Polycom®, Inc. 796
SEPARATE_MANAGEMENT_NET
WORK
Enables/disables the Network Separation. Can only be disabled in
the Ultra Secure Mode (ULTRA_SECURE_MODE=YES).
Default: NO.
SESSION_TIMEOUT_IN_MINUTES If there is no input from the user or if the connection is idle for
longer than the number of minutes specified by this flag, the
connection to the Collaboration Server is terminated.
If the ULTRA_SECURE_MODE = NO:
• Range: 0-999
• Default: 0 (Feature is disabled.)
If the ULTRA_SECURE_MODE = YES:
• Range: 0-999
• Default: 10
SET_AUDIO_CLARITY Audio Clarity improves received audio from participants connected
via low audio bandwidth connections, by stretching the fidelity of
the narrowband telephone connection to improve call clarity. The
enhancement is applied to the following low bandwidth (4kHz)
audio algorithms:
• G.729a
• G.711
Note:
This flag sets the initial value for Audio Clarity during First-time
Power-up. Thereafter the feature is controlled via the Profile
Properties > Audio Settings dialog box.
Possible Values: ON / OFF
Default: OFF
For more information see Defining New Profiles.
SET_AUDIO_PLC Packet Loss Concealment (PLC) for Siren audio algorithms
improves received audio when packet loss occurs in the network.
The following audio algorithms are supported:
• Siren 7 (mono)
• Siren 14 (mono/stereo)
• Siren 22 (mono/stereo)
Possible Values: ON / OFF
Default: ON
Note: The speaker’s endpoint must use a Siren algorithm for
audio compression.
The MCMS System Flags
Flag Description Add?