EasyManua.ls Logo

Polysoude P6 - Programmed Welding Parameters Reference; Gas Axis Parameters

Default Icon
92 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
THE ART OF WELDING
P6
PN-0509076 Rev. 16 81-92
List of programmed welding parameters7. 2.
Gas axis
Function Wording Ref. Min. Max. Unit Increment Default
Prepurge time Pregas time T10 1.0 999,0 s 0.1 10.0
Postpurge time Postgas time T11 1.0 999,0 s 0.1 10.0
Oxygen ow rate control
Oxygen
threshold
L10 1.0 206400 ppm 0.1 50.0
Current axis
Function Wording Ref. Min. Max. Unit Increment Default
Ignition current Ignition current I20 5 300 A 1 25
Prefusion ramp time Ramp time T20 0 9999 s 1 0
High current High current I22 5.0 300.0 A 0.1 10
High current time Pulse time high T22 0 or 10 3000 ms 1 100
Low current Low current I23 5.0 300.0 A 0.1 5
Low current time Pulse time low T23 0 or 10 3000 ms 1 100
Start of downslope Start downslope N20 361 9999 ° 1 365
Downslope time Downslope time T25 0.1 60.0 s 0.1 3.0
Arc cut-off current
Arc cut-off
current
I25 5 300 A 1 5

Table of Contents

Related product manuals