Running Media Patrol (CLU)
Media Patrol is a routine maintenance procedure that checks the magnetic media on each disk drive.
Media Patrol checks all physical drives assigned to disk arrays and spare drives. It does not check
uncongured drives.
To start, stop, pause or resume Media Patrol - Main Menu >> Subsystem Management >>
Media Patrol >> [Start, Stop, Pause, or Resume]. If you choose Stop, press Y to conrm.
Locking or Unlocking the Subsystem (CLU)
The lock prevents other sessions (including sessions with the same user) from making a conguration
change to the controller until the lock expires or a forced unlock is done. When the user who locked
the controller logs out, the lock is automatically released.
Setting the Lock
To set the lock:
1. Main Menu >> Subsystem Management >> Lock Management
2. In the Lock Time eld, type a lock time in minutes.
1440 minutes = 24 hours
3. Highlight Lock and press Enter.
Resetting the Lock
To reset the lock with a new time:
1. Main Menu >> Subsystem Management >> Lock Management
2. In the Lock Time eld, type a lock time in minutes.
1 to 1440 minutes (24 hours)
3. Highlight Renew and press Enter.