84
Vess A6000 Series NVR Server Promise Technology
COntrOller SettingS
To make controller settings:
1. Click the Controllers icon.
2. Click the specic Controller icon of the controller you want to manage.
3. Click the Settings tab.
4. Make settings changes as required:
• Enter,changeordeletethealiasintheAliaseld.
• Coercion–Checktheboxtoenableorunchecktodisable.
• CoercionMethod–Chooseamethodfromthedrop-downmenu:
GBTruncate
10GBTruncate
GrpRounding
TableRounding
• WriteBackCacheFlushInterval–Enteravalueintotheeld,1to12seconds.
• HDDPowerSaving–Choosetimeperiodsfromthedrop-downmenus.
AfteranHDDhasbeenidleforthesetperiodoftime:
PowerSavingIdleTime–Parkstheread/writeheads.
PowerSavingStandbyTime–Lowersdiskrotationspeed.
PowerSavingStoppedTime–Spinsdownthedisk(stopsrotation).
• HostCacheFlushing–Checktheboxtoenableorunchecktodisable.
• ForcedReadAhead(cache)–Checktheboxtoenableorunchecktodisable.
• PhysicalDriveTemperatureThreshold-Typeatemperature
(50-55ºC)totriggeraneventnoticeandemailalert.
• PhysicalDriveCriticalTemperatureThreshold-Typea
temperature(58-65ºC)totriggersystemshutdown.
5. Click the Submit button.