COMMUNICATIONS PROTOCOL TCP/IP communications setup command set
CubiScan 325 Service Manual 78
TCP/IP command set summary
The table below shows the Command Set Summary for TCP/IP.
(A) - Command Character
(B) - Command Hex Value(s)
Read gateway address
This command is used to read the current gateway address setting from the Cubiscan 325.
TCP configuration name (A) (B) Page
“Read gateway address” ~G 40h+47h 78
“Set gateway address” @G 7Eh+47h 79
“Read IP address” ~I 40h+49h 80
“Set subnet address” @I 7Eh+49h 81
“Set subnet address” ~M 40h+4Dh 82
“Set MAC address” @M 7Eh+4Dh 83
“Read port” ~P 40h+50h 84
“Set port” @P 7Eh+50h 84
“Read subnet address” ~N 40h+4Eh 85
“Set subnet address” @N 7Eh+4Eh 86
Pos Len Description Type Range ASCII
Command format
1 1 Start of text Control (STX) 02h
2 1 Read command Alpha (~) 7Eh
31
Gateway address
command
Alpha (G) 47h
4 1 End of text Control (ETX) 03h
5 1 Carriage return Control (CR) 0Dh
6 1 Line feed Control (LF) 0Ah
Acknowledge format
1 1 Start of text Control (STX) 02h
2 1 Read command Alpha (~) 7Eh
31
Gateway address
command
Alpha (G) 47h
4 1 Acknowledge Alpha (A) 41h
5
7-15
or n
IP address Alpha (0.0.0.0) to
(255.255.255.255)