COMMUNICATIONS PROTOCOL Cubiscan 325 command set
CubiScan 325 Service Manual 65
Save parameters
This command causes the Cubiscan 325 to save all current parameters to the file param125.txt on
the SD card.
6 1 Line feed Control (LF) 0Ah
Negative acknowledge format
1 1 Start of text Control (STX) 02h
2 1 Reset command Alpha (x) 78h
3 1 Neg. acknowledge Alpha (N) 4Eh
4 1 End of text Control (ETX) 03h
5 1 Carriage return Control (CR) 0Dh
6 1 Line feed Control (LF) 0Ah
Pos Len Description Type Range ASCII
Command format
1 1 Start of text Control (STX) 02h
2 1 Save command Alpha (.) 2Eh
3 1 End of text Control (ETX) 03h
4 1 Carriage return Control (CR) 0Dh
5 1 Line feed Control (LF) 0Ah
Acknowledge format
1 1 Start of text Control (STX) 02h
2 1 Save command Alpha (.) 2Eh
3 1 Acknowledge Alpha (A) 41h
4 1 End of text Control (ETX) 03h
5 1 Carriage return Control (CR) 0Dh
6 1 Line feed Control (LF) 0Ah
Negative acknowledge format
1 1 Start of text Control (STX) 02h
2 1 Save command Alpha (.) 2Eh
3 1 Neg. acknowledge Alpha (N) 4Eh
4 1 End of text Control (ETX) 03h
5 1 Carriage return Control (CR) 0Dh
6 1 Line feed Control (LF) 0Ah
Pos Len Description Type Range ASCII