COMMUNICATIONS PROTOCOL TCP/IP communications setup command set
CubiScan 325 Service Manual 83
Set MAC address
This command is used to set the MAC address on the Cubiscan 325.
Pos Len Description Type Range ASCII
Command format
1 1 Start of text Control (STX) 02h
2 1 Set command Alpha (@) 40h
3 1 MAC address command Alpha (M) 4Dh
512
Mac address Alpha 000000000000-
FFFFFFFFFFFFF
17 1 End of text Control (ETX) 03h
18 1 Carriage return Control (CR) 0Dh
19 1 Line feed Control (LF) 0Ah
Acknowledge format
1 1 Start of text Control (STX) 02h
2 1 Set command Alpha (@) 02h
3 1 MAC address command Alpha (M) 4Dh
4 1 Acknowledge Alpha (A) 41h
5 1 End of text Control (ETX) 03h
6 1 Carriage return Control (CR) 0Dh
7 1 Line feed Control (LF) 0Ah
Negative acknowledge format
Pos Len Description Type Range ASCII
1 1 Start of text Control (STX) 02h
2 1 Set command Alpha (@) 40h
3 1 MAC address command Alpha (M) 4Dh
4 1 Neg. acknowledge Alpha (N) 4Eh
5 1 End of text Control (ETX) 03h
6 1 Carriage return Control (CR) 0Dh
7 1 Line feed Control (LF) 0Ah