COMMUNICATIONS PROTOCOL Cubiscan 325 command set
CubiScan 325 Service Manual 57
Factor table
This command causes the Cubiscan 325 to store new dimensional weight factors. There are eight
factors used, depending on the current shipping mode (international or domestic), dimension
unit (in or cm), and weight unit (lb or kg).
Pos Len Description Type Range ASCII
Command format
1 1 Start of text Control (STX) 02h
2 1 Factor toggle command Alpha (f) 66h
3 4 Dom. In/Lb Numeric 0000-9999
7 1 Comma Alpha (,) 2Ch
8 4 Int. In/Lb Numeric 0000-9999
12 1 Comma Alpha (,) 2Ch
13
4
Dom. In/Kg Numeric 0000-9999
17
1
Comma Alpha (,) 2Ch
18
4
Int. In/Kg Numeric 0000-9999
22
1
Comma Alpha (,) 2Ch
23
4
Dom. Cm/Lb Numeric 0000-9999
27
1
Comma Alpha (,) 2Ch
28
4
Int. Cm/Lb Numeric 0000-9999
32
1
Comma Alpha (,) 2Ch
33
4
Dom. Cm/Kg Numeric 0000-9999
37
1
Comma Alpha (,) 2Ch
38
4
Int. Cm/Kg Numeric 0000-9999
42
1
End of text Control (ETX) 03h
43
1
Carriage return Control (CR) 0Dh
44
1
Line feed Control (LF) 0Ah
Acknowledge format
1 1 Start of text Control (STX) 02h
2 1 Factor table command Alpha (f) 66h
3 1 Acknowledge Alpha (A) 41h
4 1 End of text Control (ETX) 03h
5 1 Carriage return Control (CR) 0Dh