-125-
S
Fault List CM
Buzzer sounds
Buzzer sounds intermittently
after fault identification and
after switching on the unit.
Reason of fault:
Any thermo couple is defective
Check connector of
thermocouple for sufficient
contact.
Change defective
thermocouple.
Indication E3 or E4
or E5 or E6?
E3 = Interior cabinet sensor B1
E4 = Quenching sensor B2
E5 = Core temp. sensor B3
E6 = Sensor steam generator B5
Unit out of order
Indication
E 7?
Thermo couple of pcb defective,
change pcb
Info
Yes
No