EasyManuals Logo

Rauch QUANTRON User Manual

Rauch QUANTRON
110 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #38 background imageLoading...
Page #38 background image
Both displays are calculated based on the following values:
Fertiliser settings
Input in the remaining quantity input field
Application rate
Working width
u
Access the menu Weighing/Trip count.> Rest (kg, ha, m).
The Rest menu appears.
For weighing spreaders the current fill weight can only be determined by weighing. In all other
spreaders, the remaining fertilizer quantity is calculated from the fertilizer and machine settings as
well as from the drive signal, and the filling quantity must be entered manually (see below).
The Application rate and Working width values cannot be changed in this menu. They are for
information purposes only.
Fig. 19: Menu kg left
[1] Remaining quantity input field
[2] Application rate, display field from Fertiliser
settings
[3] Working width, display field from Fertiliser
settings
[4] Display of the area that can be spread
[5] Display of the distance that can be spread
u
Access the menu Weighing/Trip count. > Rest (kg, ha, m).
The remaining quantity from the last spreading process is displayed.
u
Fill the hopper.
u
In the kg field, enter the new total weight of the fertilizer in the hopper.
u
Press the Enter key
The unit calculates the values for the possible spread area and distance.
4. Operation
38
5902662 QUANTRON-A AXIS/MDS

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rauch QUANTRON and is the answer not in the manual?

Rauch QUANTRON Specifications

General IconGeneral
BrandRauch
ModelQUANTRON
CategoryControl Unit
LanguageEnglish

Related product manuals