The language package for your country is pre-set at the factory.
u
Access the System/Test > Language menu.
The display shows the first of four pages.
Fig. 40: Language sub-menu, page 1
u
Select the language for the menus.
The languages are listed in several menu windows. The arrow keys enable switching to the next or
previous windows.
u
Press the Enter key.
The selection is confirmed.
The QUANTRON-A control unit restarts automatically.
The menus are displayed in the selected language.
4.10.2 Display configuration
The three display fields in the operating screen can be individually adjusted and assigned the following
values as desired:
Forward speed
Flow factor (FF)
ha trip
kg trip
m trip
kg left
m left
ha left
Idle time (Time until the next idle measurement)
Torque for the spreading disc drive
4. Operation
QUANTRON-A AXIS/MDS 5902662
75