PG-FP5 CHAPTER 4 PROGRAMMING GUI USAGE
R20UT0008EJ0400 Rev. 4.00 Page 95 of 240
Jul 15, 2010
[Vdd monitoring] check box
When supplying V
DD from the target system ([On Target] check box: selected), whether to enable the VDD pin
power supply detection function can be selected with this check box. Select to enable, or clear to disable the
function.
Caution When the V
DD pin power supply detection function is disabled, the product can be used even if
the V
DD pins in the FP5 and the target system are not connected. In such a case, make sure
that VDD power generated in the target system always matches the output signal power supply
generated in the FP5.
[Wide Voltage mode] check box
This check box can be used to select whether to use wide-voltage mode or full-speed mode. If this check box is
checked, commands are executed in wide-voltage mode. If this check box is not checked, commands are
executed in full-speed mode. This check box becomes available when a device that supports this function is
selected. For details about wide-voltage mode and full-speed mode, see the user's manual of the target device.
Caution When loading an HCUHEX file, the HCUHEX file is handled as master data, so the HCUHEX file
settings are applied to the target device. The setting of this check box therefore cannot be
changed.
[FLMD0] (or Vpp[V]), [CLK], [RESET], [Serial Out] and [Serial In] boxes
Through the PR5 file, this box displays the various default terminal levels. FLMD0 (or Vpp[V]) uses volt (V) units,
CLK uses Vdd or Vdd2, RESET uses Vdd or VDD Reset TrigIn, and Serial Out and Serial In use Vdd. Note that
VDD Reset TrigIn is displayed when the [Enable target RESET] check box of the [Command options] area is
enabled.