System Service Mode
SM Appendix 9-9 D037/D038/D040/D041
Appendix:
SP Mode
Tables
Target Temp. After Ready *ENG
[140 to 165 / 160 / 1 deg/step]
082
Specifies the target temperature for the maintain mode after the machine has
reached the target temperature in warm-up mode.
Recovery Target Temp. *ENG
[140 to 160 / 155 / 1 deg /step]
083
Specifies the target temperature for the print mode without printing/copying job
after the machine's recovery.
087 Thick 2: FC: Simplex: Ends *ENG
088 Thick 2: BW: Simplex: Ends *ENG
[135 to 180 / 160 / 1 deg/step]
089 Thick 3: FC: Simplex: Center *ENG
090 Thick 3: FC: Simplex: Ends *ENG
091 Thick 3: BW: Simplex: Center *ENG
092 Thick 3: BW: Simplex: Ends *ENG
[135 to 180 / 165 / 1 deg/step]
109 M-Thick:FC:Simplex:Center *ENG
110 M-Thick:FC:Duplex:Center *ENG
111 M-Thick: BW: Simplex:Center *ENG
112 M-Thick: BW: Duplex:Center *ENG
113 M-Thick: FC: Simplex: Ends *ENG
114 M-Thick: FC: Duplex: Ends *ENG
115 M-Thick: BW: Simplex: Ends *ENG
116 M-Thick: BW: Duplex: Ends *ENG
[125 to 175 / 155 / 1 deg/step]
120 Plain2: FC: Simplex:Center *ENG
121 Plain2: FC: Simplex:Ends *ENG
122 Plain2: FC: Duplex:Center *ENG
123 Plain2: FC: Duplex:Ends *ENG
[125 to 175 / 150 / 1 deg/step]