System Service Mode
D037/D038/D040/D041 9-12 SM Appendix
170 SP 6:BW:Duplex:Center *ENG
171 SP 6:BW:Duplex:Ends *ENG
172 F:SP 1:FC:Simplex:Center *ENG
173 F:SP 1:FC:Simplex:Ends *ENG
174 F:SP 1:BW:Simplex:Center *ENG
175 F:SP 1:BW:Simplex:Ends *ENG
[110 to 160 / 130 / 1 deg/step]
176 F:SP 2:FC:Simplex:Center *ENG
177 F:SP 2:FC:Simplex:Ends *ENG
178 F:SP 2:BW:Simplex:Center *ENG
179 F:SP 2:BW:Simplex:Ends *ENG
[110 to 160 / 135 / 1 deg/step]
180 F:SP 3:FC:Simplex:Center *ENG
181 F:SP 3:FC:Simplex:Ends *ENG
182 F:SP 3:BW:Simplex:Center *ENG
183 F:SP 3:BW:Simplex:Ends *ENG
[110 to 160 / 125 / 1 deg/step]
[Fusing Temperature Display] Fusing Temperature Display (Heating or
Pressure)
1106
Displays the current temperature of the heating and pressure rollers.
001 Fusing Roller: Center - [–20 to 250 / 0 / 1 deg/step]
002 Fusing Roller: Ends - [–10 to 250 / 0 / 1 deg/step]
The heating roller has two lamps. One heats the center of the heating roller
and the other heats both ends of the heating roller.
003 Pressure Roller: Center - [–10 to 250 / 0 / 1 deg/step]
004 Pressure Roller:Ends - [–10 to 250 / 0 / 1 deg/step]