System Service Mode
SM Appendix 9-43 D037/D038/D040/D041
Appendix:
SP Mode
Tables
2181 [Line Pos. Adj. Result]
Displays the values for each correction.
 "Paper Int. Mag: Subdot" indicates the magnification correction value
between two sheets of paper.
 "Mag.Cor. Subdot" indicates the magnification correction value.
 "M. Scan Erro." indicates the shift correction value in the main scan
direction.
 "S. Scan Erro." Indicates the shift correction value in the sub scan
direction.
 "M. Cor.: Dot" indicates the dot correction value in the main scan direction.
 "M. Cor.: Subdot" indicates the sub dot correction value in the main scan
direction.
 Bk: Black, M: Magenta, C: Cyan, Y: Yellow
001 Paper Int. Mag: Subdot: Bk *ENG
[–32768 to 32767 / 0 / 1 pulse/step]
002 Mag.Cor. Subdot: Bk *ENG
[–32768 to 32767 / 0 / 1 pulse/step]
003 Skew: C *ENG
004 Bent: C *ENG
005 M. Scan Shift: Left: C *ENG
006 M. Scan Shift: Center: C *ENG
007 M. Scan Shift: Right: C *ENG
008 S. Scan Shift: Left: C *ENG
009 S. Scan Shift: Center: C *ENG
010 S. Scan Shift: Right: C *ENG
[–5000 to 5000 / 0 / 0.001 um/step]
011 M. Cor.: Dot: C *ENG
[–512 to 511 / 0 / 1 dot/step]
012 M. Cor.: Subdot: C *ENG
[–15 to 15 / 0 / 1 pulse/step]
013 Paper Int. Mag: Subdot: C *ENG
014 Mag.Cor. Subdot: C *ENG
[–32768 to 32767 / 0 / 1 pulse/step]