System Service Mode
SM Appendix 9-203 D037/D038/D040/D041
Appendix:
SP Mode
Tables
5504 [Jam Alarm]
*CTL -
001
Sets the alarm to sound for the specified jam level (document misfeeds are
not included).
[0 to 3 / 3 / 1 /step]
0: Zero (Off)
1: Low (2.5K jams)
2: Medium (3K jams)
3: High (6K jams)
[Error Alarm]
5505
Sets the error alarm level.
The error alarm counter counts "1" when any SC is detected. However, the
error alarm counter decreases by "1" when an SC is not detected during a set
number of copied sheets (for example, default 1500 sheets).
The error alarm occurs when the SC error alarm counter reaches "5".
001 - *CTL
[0 to 255 / 20 / 100 copies /step]
5507 [Supply Alarm]
*CTL -
001 Paper Supply Alarm
0: Off, 1: On, DFU
002 Staple Supply Alarm
0: Off, 1: On, Japan only
003 Toner Supply Alarm
0: Off, 1: On, DFU
080 Toner Call Timing
Changes the timing of the “Toner Supply Call” via
the @Remote, when the following conditions
occur.
0: At replacement
1: At near end
128 Interval :Others
132 Interval :A3
133 Interval :A4
[250 to 10000 / 1000 / 1 /step] DFU