5505
[Error Alarm]
Sets the error alarm level.
The error alarm counter counts "1" when any SC is detected. However, the error alarm
counter decreases by "1" when an SC is not detected during a set number of copied
sheets (for example, default 1500 sheets).
The error alarm occurs when the SC error alarm counter reaches "5".
001 - *CTL [0 to 25500 / 1000 / 100/step]
5507
[Supply Alarm] *CTL -
Enables or disables the notifying a supply call via the @Remote.
001 Paper Supply Alarm
[0 or 1 / 0 / - ]
0: Off, 1: On
003 Toner Supply Alarm
[0 or 1 / 1 / - ]
0: Off, 1: On
080 Toner Call Timing
[0 or 1 / 0 / - ]
Changes the timing of the "Toner Supply
Call" via the @Remote, when the following
conditions occur.
0: At replacement
1: At near end
128 Interval :Others
[250 to 10000 / 1000 / 1 /step]
133 Interval :A4
134 Interval :A5
142 Interval :B5
164 Interval :LG
166 Interval :LT
172 Interval :HLT
5508 [CC Call] *CTL -
3. SP Mode Tables
284