173 Modem Serial No.
This SP displays the serial number registered for the
RCG-M.
174
Retransmission Ringing
Normally, it is best to allow unlimited time for certification and ID2 update requests, and
for the notification that the certification has been completed. However, RCG-M
generates charges based on transmission time for the customer, so a limit is placed upon
the time allowed for these transactions.
If these transactions cannot be completed within the allowed time, do this SP to cancel
the time restriction.
186
RCG-C M DebugBitSW
-
187
FAX TX Priority -
This SP determines whether pushing the off-hook button will interrupt a RCG-M
transmission in progress to open the line for fax transaction. This SP can be used only if
SP5816 164 is set to "0".
[0 or 1/ 0 / - ]
0: Disable, 1: Enable
200 Manual Polling - Executes the manual polling.
201
Regist Status
Displays a number that indicates the status of the @Remote service device.
0: Neither the registered device by the external nor embedded RCG device is set.
1: The embedded RCG device is being set. Only Box registration is completed. In this
status, this unit cannot answer a polling request from the external RCG.
2. The embedded RCG device is set. In this status, the external RCG unit cannot answer
a polling request.
3. The registered device by the external RCG is being set. In this status the embedded
RCG device cannot be set.
4 The registered module by the external RCG has not started.
202 Letter Number
Allows entry of the number of the request needed for the
RCG-N device.
203 Confirm Execute Executes the inquiry request to the @Remote GW URL.
3. SP Mode Tables