142 Postcard:Thick1:FC:Press *ENG [0 to 200 / 150 / 1deg/step]
145 Postcard:Thick2:FC:Center *ENG [100 to 180 / 130 / 1deg/step]
146 Postcard:Thick2:FC:Press *ENG [0 to 200 / 150 / 1deg/step]
149 Postcard:Thick3:FC:Center *ENG [100 to 180 / 130 / 1deg/step]
150 Postcard:Thick3:FC:Press *ENG [0 to 200 / 150 / 1deg/step]
1106
[Fusing Temp. Display] Fusing Temperature Display (Heating or Pressure)
Displays the current temperature of the heating and pressure rollers.
001 Center ENG [-50 to 250 / 0 / 1deg/step]
002
End ENG [-20 to 348 / 0 / 1deg/step]
The heating roller has two lamps. One heats the center of the heating roller and the other
heats both ends of the heating roller.
003
Pressure: Center ENG [-20 to 250 / 0 / 1deg/step]
The pressure roller has two lamps. One heats the center of the heating roller and the
other heats both ends of the heating roller.
005 Pressure: End ENG [-20 to 250 / 0 / 1deg/step]
1107 [Standby Target Temp. Setting]
001
Stanby/Preheat1:Center *ENG [0 to 100 / 60 / 1deg/step]
Specifies the time that the fusing heater turns off after the fusing unit temperature has
reached its target temperature.
003
Preheat2:Center *ENG [-50 to 100 / -50 / 1deg/step]
Specifies the temperature of the heating roller for the ready or energy save 2 mode.
005
Low Power:Center *ENG [-50 to 100 / -50 / 1deg/step]
Specifies the temperature of the heating roller for the low power mode.
007
Print Ready:Center *ENG [0 to 180 / 150 / 1deg/step]
Specifies the temperature of the heating roller for the print ready condition.
3. SP Mode Tables