102 Heat Off Time:Start:Print Ready *ENG [0 to 10000 / 500 / 1msec/step]
111
Heat Off Time:Stop:After
Reload/Print Ready
*ENG [0 to 10000 / 0 / 1msec/step]
112 Heat Off Time:Stop:After Job *ENG [0 to 10000 / 0 / 1msec/step]
113
Heat Off Time:Stop:After
Job:BW2
*ENG [0 to 10000 / 0 / 1msec/step]
114 Temp.: Center *ENG [0 to 200 / 160 / 1deg/step]
115
Heat Off Time:Stop:Warm
UP:BW2
*ENG [0 to 10000 / 3300 / 1msec/step]
1122
[Standby Rotation Setting]
Sets the interval between fusing roller idle rotations during standby.
001 Rotation Interval *ENG [0 to 240 / 60 / 1min/step]
002 Rotation Time *ENG [0 to 10000 / 5 / 1msec/step]
1123
[Paper Jam Rotation Setting]
-
001 Normal Rotation Distance *ENG [1 to 10000 / 1 / 1mm/step]
002 Reverse Rotation Distance *ENG [1 to 10000 / 70 / 1mm/step]
1124
[CPM Down Setting]
Sets the temperature differential used to calculate CPM down for low and high
temperatures. Also, sets the interval for temperature checks for CPM down.
001 Low:Down Temp. *ENG [-50 to 0 / -20 / 1 deg/step]
002 Low:Up Temp. *ENG [-50 to 0 / -15 / 1 deg/step]
003 Low :1st CPM *ENG [10 to 100 / 80 / 1 %/step]
004 Low :2nd CPM *ENG [10 to 100 / 65 / 1 %/step]
005 Low :3rd CPM *ENG [10 to 100 / 50 / 1 %/step]
006 High:1st CPM :Plain1:BW:LT *ENG [10 to 100 /100 / 1%/step]
Main SP Tables-1