003 Environmental Target: M *ENG [0 to 2000 / 650 / 10uA/step]
004 Environmental Target: Y *ENG [0 to 2000 / 650 / 10uA/step]
2012
[Charge Output Control]
Selects the AC voltage control type.
001 AC Voltage *ENG [0 or 1 / 0 / 1/step]
2013 [Environmental Correction: PCU]
001 Current Environmental: Display *ENG
Displays the environmental condition,
which is measured in absolute humidity.
[0 to 5 / - / 1/step]
1: LL (LL <= 4.3 g/m
3
)
2: ML (4.3 < ML <= 11.3 g/m
3
)
3: MM (11.3 < MM <= 18.0 g/m
3
)
4: MH (18.0 < MH <= 24.0 g/m
3
)
5: HH (24.0 g/m
3
< HH)
002 Forced Setting *ENG
Selects the environmental condition
manually. DFU
[0 to 5 / 0 / 1/step]
0: The environmental condition is
determined automatically.
1: LL, 2: ML, 3: MM, 4: MH, 5: HH
003 Absolute Humidity: Threshold 1 *ENG
Changes the humidity threshold between LL
and ML. DFU
[0.00 to 100.00 / 4.30 / 0.01 g/m
3
/
step]
004 Absolute Humidity: Threshold 2 *ENG
Changes the humidity threshold between
ML and MM. DFU
[0.00 to 100.00 / 11.30 / 0.01 g/m
3
/
step]
3. SP Mode Tables