001 Bk *ENG
Displays the number of no toner detections with
end sensor.
[0 to 99 / - / 1times/step]
002 C *ENG
003 M *ENG
004 Y *ENG
3123 [TE Sn Status: Display]
021 Latest Output: Bk *ENG
Displays the latest output with end sensor.
[0 or 1 / - / 1/step]
0: Not output, 1: Output
022 Latest Output: C *ENG
023 Latest Output: M *ENG
024 Latest Output: Y *ENG
3131 [Vt TE Thresh]
001 Delta Vt Thresh *ENG
Sets toner end threshold to sum delta Vt after
NE.
[0.00 to 5.00 / 0.50 / 0.01V/step]
002 Delta Vt Sum Thresh *ENG
Sets toner end threshold for TE detection delta
Vt after NE.
[0 to 99 / 10 / 1V/step]
011 Delta Vt Thresh BF NE *ENG
Sets toner end threshold to sum delta Vt before
NE.
[0.00 to 5.00 / 0.50 / 0.01V/step]
012 Delta Vt Sum Thresh BF NE *ENG
Sets toner end threshold for TE detecion delta
Vt before NE.
[0 to 99 / 10 / 1V/step]
021 High TC Delta Vt Thresh *ENG [0.00 to 5.00 / 0.30 /0.01V/step]
022 High TC Delta Vt Sum Thresh *ENG [0 to 99/ 3 / 1V/step]
023
High TC Delta Vt Thresh BF
NE
*ENG [0.00 to 5.00 / 0.70 / 0.01V/step]
024
High TC Delta Vt Sum Thresh
BF NE
*ENG [0 to 99 / 10 / 1V/step]
3. SP Mode Tables