001 Std Speed Slope:K *ENG
[-1000 to 1000 / 186 / 1/step]
002 Std Speed Slope:C *ENG
003 Std Speed Slope:M *ENG
004 Std Speed Slope:Y *ENG
011 Std Speed intercept:K *ENG [-1000 to 1000 / 6 / 1/step]
012 Std Speed intercept:C *ENG
[-1000 to 1000 / 8 / 1/step]013 Std Speed intercept:M *ENG
014 Std Speed intercept:Y *ENG
041 Low Speed Slope:K *ENG
[-1000 to 1000 / 144 / 1/step]
042 Low Speed Slope:C *ENG
043 Low Speed Slope:M *ENG
044 Low Speed Slope:Y *ENG
051 Low Speed intercept:K *ENG [-1000 to 1000 / 26 / 1/step]
052 Low Speed intercept:C *ENG
[-1000 to 1000 / 28 / 1/step]053 Low Speed intercept:M *ENG
054 Low Speed intercept:Y *ENG
3624 [TC Adj. Mode]
001 Target(Upp Limit) *ENG
Sets the upper limit of the target range of
developer gamma adjustment for toner density
adjustment process control.
[0.00 to 1.00 / 0.15 / 0.01mg/cm^2/-kV/
step]
002 Target(Lwr Limit) *ENG
Sets the lower limit of the target range of
developer gamma adjustment for toner density
adjustment process control.
[0.00 to 1.00 / -0.15 / 0.01mg/cm^2/-kV/
step]
Main SP Tables-3