002 Original Count Alarm *CTL
[0 or 1 / 0 / 1/step]
0: No alarm sounds
1: Alarm sounds after the number of
originals passing through the ARDF >
10,000
5504 [Jam Alarm]
001 Jam Alarm *CTL
Sets the alarm to sound for the specified
jam level (document miss feeds are not
included).
[0 to 3 / 3 / 1/step]
0: Zero (Off)
1: Low (2.5K jams)
2: Medium (3K jams)
3: High (6K jams)
5505
[Error Alarm]
Sets the error alarm level.
The error alarm counter counts "1" when any SC is detected. However, the error alarm
counter decreases by "1" when an SC is not detected during a set number of copied
sheets (for example, default 1500 sheets).
The error alarm occurs when the SC error alarm counter reaches "5".
001 Error Alarm *CTL [0 to 255 / 10 / 1hundred/step]
5507
[Supply Alarm]
Enables or disables the notifying a supply call via the @Remote.
001 Paper Supply Alarm *CTL
[0 or 1 / 0 / 1/step]
0: OFF, 1: ON
003 Toner Supply Alarm *CTL
[0 or 1 / 1 / 1/step]
0: OFF, 1: ON