1952
[Fan Control Off Mode Time Set]
Specifies the time for fan control off mode.
001 - *ENG [0 to 60 / 10 / 1min/step]
1953
[Extra Fan Control]
Configures the settings of extra fan control.
001
Extra Fan Cooling State *ENG
[0 or 1 / - / 1/step]
Off, 1: On
Displays the extra fan cooling is On or Off.
006
Execution Temp. Threshold *ENG [0.0 to 100.0 / 42.0 / 0.1deg/step]
Specifies the judgment temperature for the starting of extra fan execution.
007
Cancellation Temp. Threshold *ENG [0.0 to 100.0 / 5.0 / 0.1deg/step]
Specifies the threshold temperature (the difference in value with the starting of extra fan
execution) for the cancellation of extra fan execution.
008
fan setting with or without
operation
*ENG [0 or 1 / - / 1/step]
Enables or disenables the control of extra fan execution control.
0: Disenable
1: Enable
1954
-
Fan low noise mode end temperature
001 Fan Half Speed Control *ENG [0 to 100 / 30 / 0.1deg/step]
5. System Maintenance