027 Toner Sub-hopper: K *ENG
Sets the flag for new toner sub hopper manual
settings.
[0 or 1 / 0 / 1/step]
0: OFF, 1: ON
028 Toner Sub-hopper: C *ENG
029 Toner Sub-hopper: M *ENG
030 Toner Sub-hopper: Y *ENG
3710 [HST Concentration Control: Set]
001 Control Method: Selection *ENG
Sets the select mode if control is done or not
with HST memory.
[0 or 1 / 1 / 1/step]
0:NotUse, 1:Use
3711 [HST Concentration Control: K]
001 Vcnt *ENG Displays release check value stored in HST
memory.
[0.0 to 5.0 / - / 0.1V/step]
002 Vt *ENG
003 Sensitivity: HL *ENG
Displays release check value stored in HST
memory.
[1.22 to 3.77 / - / 0.01V/step]
004 Sensitivity: HM *ENG Displays release check value stored in HST
memory.
[0.00 to 2.55 / - / 0.01V/step]
005 Sensitivity: ML *ENG
006 Set Detection *ENG
Displays release check value stored in HST
memory.
[0.0 to 5.0 / - / 0.1V/step]
007 Without Developer *ENG
008 With Developer *ENG
009 Serial Number 1 *ENG Displays release check value stored in HST
memory.
[0 to 255 / - / 1/step]
010 Serial Number 2 *ENG
011 Adjustment: Vt *ENG Displays adjustment value stored in HST
memory.
[0.0 to 5.0 / - / 0.1V/step]
012 Adjustment: Vtref *ENG