014 Adjustment: Gamma *ENG
Displays adjustment value stored in HST
memory.
[0.00 to 2.55 / - / 0.01mg/cm2/-kV/step]
015 Adjustment: Vcnt Result *ENG
Displays adjustment value stored in HST
memory.
[0 to 9 / - / 1/step]
3713
[HST Concentration Control: M]
Displays release check value stored in HST memory.
001 Vcnt *ENG Displays release check value stored in HST
memory.
[0.0 to 5.0 / - / 0.1V/step]
002 Vt *ENG
003 Sensitivity: HL *ENG
Displays release check value stored in HST
memory.
[1.22 to 3.77 / - / 0.01V/step]
004 Sensitivity: HM *ENG Displays release check value stored in HST
memory.
[0.00 to 2.55 / - / 0.01V/step]
005 Sensitivity: ML *ENG
006 Set Detection *ENG
Displays release check value stored in HST
memory.
[0.0 to 5.0 / - / 0.1V/step]
007 Without Developer *ENG
008 With Developer *ENG
009 Serial Number 1 *ENG Displays release check value stored in HST
memory.
[0 to 255 / - / 1/step]
010 Serial Number 2 *ENG
011 Adjustment: Vt *ENG Displays adjustment value stored in HST
memory.
[0.0 to 5.0 / - / 0.1V/step]
012 Adjustment: Vtref *ENG
013 Adjustment: Vtcnt *ENG
Displays adjustment value stored in HST
memory.
[0.00 to 5.00 / - / 0.01V/step]
5. System Maintenance