001 to
027
Displays the number of sheets printed for each current maintenance unit.
PM counters click up based on the number of A4 (LT) LEF size sheets printed. Therefore, the
A3 (DLT) Double Count is activated. The Double Count cannot be deactivated.
When a unit is replaced, the machine automatically detects that the new unit is installed.
Then, the current PM counter value is automatically moved to the PM Counter – Previous
(SP7-906-1 to 10) and is reset to “0”.
The total number of sheets printed with the last unit replaced can be checked with
SP7-906-1 to 10.
The LCT is counted as the 3rd feed station.
*CTL: 001
ENG: Other than 001
[0 to 9999999 / - / - page/step]
001 Paper
002 Page: PCU: K
003 Page: PCU: C
004 Page: PCU: M
005 Page: PCU: Y
006 Page: Development Unit: K
007 Page: Development Unit: C
008 Page: Development Unit: M
009 Page: Development Unit: Y
010 Page: Developer: K
011 Page: Developer: C
012 Page: Developer: M
013 Page: Developer: Y
014 Page: Image Transfer
015 Page: Image Transfer Cleaning
016 Page: Fusing Unit