23
Error occurred when ROM
update program started
Controller program abnormal. If the second attempt
fails, replace controller board.
24 SD card access error
Make sure SD card inserted correctly, or use another
SD card.
30
No HDD available for stamp
data download
HDD connection incorrect or replace hard disks.
31
Data incorrect for continuous
download
Insert the SD card with the remaining data required for
the download, the re-start the procedure.
32
Data incorrect after download
interrupted
Execute the recovery procedure for the intended
module download, then repeat the installation
procedure.
33 Incorrect SD card version
Incorrect ROM data on the SD card, or data is
corrupted.
34
Module mismatch - Correct
module is not on the SD card)
SD update data is incorrect. Acquire the correct data
(Japan, Overseas, OEM, etc.) then install again.
35
Module mismatch - Module on
SD card is not for this machine
SD update data is incorrect. The data on the SD card is
for another machine. Acquire correct update data then
install again.
36
Cannot write module - Cause
other than E34, E35
SD update data is incorrect. The data on the SD card is
for another machine. Acquire correct update data then
install again.
40 Engine module download failed
Replace the update data for the module on the SD card
and try again, or replace the BICU board.
42
Operation panel module
download failed
Replace the update data for the module on the SD card
and try again, or replace the LCDC.
43
Stamp data module download
failed
Replace the update data for the module on the SD card
and try again, or replace the hard disks.
44
Controller module download
failed
Replace the update data for the module on the SD card
and tray again, or replace controller board.
50
Electronic confirmation check
failed
SD update data is incorrect. The data on the SD card is
for another machine. Acquire correct update data then
install again.