No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
547
-03
D
Zero cross error: low frequencies error
The zero cross signal is detected three times even though the heater relay is
off when turning on the main power.
The zero cross signal is not detected for 2 seconds even though the heater
relay is on after turning on the main power or closing the front door.
The detection error occurs twice or more in the 11 zero cross signal
detections. This error is defined when the detected number of zero cross
signals is less than 45.
Unstable frequencies from utility power line
Defective fusing lamp relay circuit
Unstable power supply
1. Turn off and on the main power switch.
2. Check the utility power line.
3. Check the connection of the PSU to controller board and replace the harness
or controller board if necessary.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
551 A
Heating roller thermistor error
The temperature at the end of the heating roller measured by the heating roller
thermistor does not exceed -11°C or -41°C for the prescribed time.
Broken thermopile or thermistor
Defective connectors
1. Check that the heating roller thermistor is firmly connected.
2. Replace the thermopile or thermistor.