002
Humidity:Threshold:M-humid *ENG [0 to 100 / 1 / 1 %/step]
Specifies the threshold between low and middle humidity.
003
Humidity:Threshold:H-humid *ENG [0 to 100 / 65 / 1 %/step]
Specifies the threshold between middle and high humidity.
004
Permit Temp.:Delta:Press:M-
humid
*ENG [0 to 200 / 100 / 1deg/step]
Specifies the threshold temperature for the curl control in middle humidity.
005
Permit Temp.:Delta:Press:H-
humid
*ENG [0 to 100 / 100 / 1deg/step]
Specifies the threshold temperature for the curl control in high humidity.
008
CPM:M-humid *ENG [0 to 100 / 80 / 1%/step]
Specifies the CPM ratio of the decurl control against to the normal operation in middle
humidity.
009
CPM:H-humid *ENG [0 to 100 / 65 / 1%/step]
Specifies the CPM ratio of the decurl control against to the normal operation in high
humidity.
1114
[Heat Storage Status]
Sets the threshold for fusing temperature correction to compensate for heat accumulated
on the pressure roller.
001 Temp.:Threshold:Press *ENG [0 to 200 / 80 / 1 deg/step]
002 Temp.:Threshold:Atmosphere *ENG [0 to 200 / 80 / 1 deg/step]
1115
[Target Temp. Correction]
Corrects the temperature based on the difference in the target temperatures of the end of
the hot roller.
001 Temp.:Delta:End *ENG -
1116 [Heat Storage FB Control]
3. SP Mode Tables