006 End Uniform Start Temp.:A4 *ENG [0 to 250 / 200 / 1deg/step]
007 End Uniform Start Temp.:A5 *ENG [0 to 250 / 190 / 1deg/step]
008 Overshoot Prevent Temp. *ENG [0 to 250 / 220 / 1deg/step]
009 Overshoot Prevent Time *ENG [0 to 100 / 10 / 1sec/step]
010 Overshoot Prevent Temp.:End *ENG [0 to 250 / 230 / 1deg/step]
011 *ENG [0 to 250 / 190 / 1deg/step]
021 *ENG [0 to 10000/ 0 / 1msec/step]
101 *ENG [0 to 10000/ 0 / 1msec/step]
102 *ENG [0 to 10000/ 0 / 1msec/step]
111 *ENG [0 to 10000/ 0 / 1msec/step]
112 *ENG [0 to 10000/ 0 / 1msec/step]
113 *ENG [0 to 10000/ 0 / 1msec/step]
114 *ENG [0 to 200/ 160 / 1deg/step]
1122
[Standby Rotation Setting]
Sets the interval between fusing roller idle rotations during standby.
001 Rotation Interval *ENG [0 to 240 / 60 / 1min/step]
002 Rotation Time *ENG [0 to 10000 / 5 / 1msec/step]
1124
[CPM Down Setting]
Sets the temperature differential used to calculate CPM down for low and high
temperatures. Also, sets the interval for temperature checks for CPM down.
001 Low:Down Temp. *ENG [-50 to 0 / -20 / 1 deg/step]
002 Low:Up Temp. *ENG [-50 to 0 / -15 / 1 deg/step]
003 Low :1st CPM *ENG [10 to 100 / 80 / 1 %/step]
004 Low :2nd CPM *ENG [10 to 100 / 65 / 1 %/step]
005 Low :3rd CPM *ENG [10 to 100 / 50 / 1 %/step]
3. SP Mode Tables
34