001 Feed Permit Condition Setting *ENG
[0 to 2 / 0: Productivety Mode / 1/
step]
0: Productivety Model
1: Fusing Quality 1
2: Fusing Quality 2
1132
[Maximum Duty Switch]
Switches maximum fixed duty level and power control.
001 Control Method Switch *ENG
[0 or 1 / 1: Power Control / 1/step]
0: Fixed duty
1: Power control
003 Power Offset *ENG [-4 to 4 / - / 1/step]
012 Voltage Detection *ENG [0.0 to 650.0 / 0.0 / 0.1V/step]
013 Temp.:Threshold Value *ENG [0 to 200 / - / 1deg/step]
1133
[Last Paper Heater OFF Control]
Sets the time to start turning off the heater after the last paper has fed.
001
Heater OFF Time:Normal
Speed:FC
*ENG [0 to 20000 / 4293 / 1msec/step]
002
Heater OFF Time:Normal
Speed:BW
*ENG [0 to 20000 / 3134 / 1msec/step]
005 Heater OFF Time:Low Speed:FC *ENG [0 to 20000 / 8572 / 1msec/step]
006 Heater OFF Time:Low Speed:BW *ENG [0 to 20000 / 6254 / 1msec/step]
007 Heater OFF Time:After State Shift *ENG [0 to 20000 / - / 1msec/step]
1134
[Effective Duty Adjustment]
Switches effective fixed duty level and power control for adjustment.
001 Control Method Switch *ENG
[0 or 1 / 1: ON / 1/step]
0: OFF
1: ON
3. SP Mode Tables