010
Time:Heat Storage Devision1 *ENG [0 to 1000 / 0 / 1sec/step]
Sepcifies the execution time 1 for the warming up in the low temperature condition.
011
Time:Heat Storage Devision2 *ENG [0 to 1000 / 0 / 1sec/step]
Sepcifies the execution time 2 for the warming up in the low temperature condition.
1190 [Flicker Control]
001 Flicker Control *ENG [0 or 1 / 0 / 1/step]
1801
[MotorSpeedAdjust]
Adjusts the speeds of each motor.
001 transportM:Plain1/2 *ENG [-4.00 to 4.00 / 0.00 / 0.01%/step]
002 transportM:Thin *ENG [-4.00 to 4.00 / 0.00 / 0.01%/step]
003 transportM:M-Thick *ENG [-4.00 to 4.00 / 0.00 / 0.01%/step]
004 transportM:Thick1 *ENG [-4.00 to 4.00 / 0.00 / 0.01%/step]
005 transportM:Thick2 *ENG [-4.00 to 4.00 / 0.00 / 0.01%/step]
006 transportM:Thick3 *ENG [-4.00 to 4.00 / 0.00 / 0.01%/step]
007 transportM:Special1 *ENG [-4.00 to 4.00 / 0.00 / 0.01%/step]
008 transportM:Special2 *ENG [-4.00 to 4.00 / 0.00 / 0.01%/step]
009 transportM:Special3 *ENG [-4.00 to 4.00 / 0.00 / 0.01%/step]
010 transportM:Envelop *ENG [-4.00 to 4.00 / 0.00 / 0.01%/step]
011 transportM:OHP *ENG [-4.00 to 4.00 / 0.00 / 0.01%/step]
012 transportM:Plain1/2:Low speed *ENG [-4.00 to 4.00 / 0.00 / 0.01%/step]
013 transportM:Thin:Low speed *ENG [-4.00 to 4.00 / 0.00 / 0.01%/step]
014 transportM:M-Thick:Low speed *ENG [-4.00 to 4.00 / 0.00 / 0.01%/step]
015 transportM:Special1:Low speed *ENG [-4.00 to 4.00 / 0.00 / 0.01%/step]
016 transportM:Special2:Low speed *ENG [-4.00 to 4.00 / 0.00 / 0.01%/step]
017 transportM:Special3:Low speed *ENG [-4.00 to 4.00 / 0.00 / 0.01%/step]
Main SP Tables-1