005 Absolute Humidity: Thresh 3 *ENG
Changes the humidity threshold between
MM and MH. DFU
[0.00 to 100.00 / 18.00 / 0.01 g/m
3
/
step]
006 Absolute Humidity: Thresh 4 *ENG
Changes the humidity threshold between
MH and HH. DFU
[0.00 to 100.00 / 24.00 / 0.01 g/m
3
/
step]
007 Current Temp.: Display *ENG
Displays the current temperature.
[0 to 100 / - / 1 deg/step]
008
Current Relative Humidity:
Display
*ENG
Displays the current relative humidity.
[0 to 100 / - / 1%RH/step]
009
Current Absolute Humidity:
Display
*ENG
Displays the absolute humidity.
[0.00 to 100.00 / - / 0.01 g/m
3
/step]
010 Previous Environmental: Display *ENG
Displays the previous environmental
condition, which is measured in absolute
humidity.
[1 to 5 / - / 1/step]
1: LL, 2: ML, 3: MM, 4: MH, 5: HH
011 Previous Temp.: Display *ENG
Displays the previous temperature.
[0 to 100 / - / 1 deg/step]
012
Previous Relative Humidity:
Display
*ENG
Displays the previous relative humidity.
[0 to 100 / - / 1%RH/step]
013
Previous Absolute Humidity:
Display
*ENG
Displays the previous absolute humidity.
[0.00 to 100.00 / - / 0.01/step]
2014 [Charge Control: Establishment]
001 Practice Interval: Power ON *ENG [0 to 2000 / 500 / 1 page/step]
002 Practice Interval: Printing *ENG [0 to 2000 / 0 / 1 page/step]
003 Judge Interval *ENG [0 to 500 / 10 / 1 page/step]
004 Temp Condition *ENG [0 to 99 / 35 / 1 deg/step]
Main SP Tables-2
69