3030 [Init TD Sensor :Exe]
001 Execute:ALL *ENG
[- / - / -]
[Execute]
002 Execute:Col *ENG
[- / - / -]
[Execute]
003 Execute:K *ENG
[- / - / -]
[Execute]
004 Execute:C *ENG
[- / - / -]
[Execute]
005 Execute:M *ENG
[- / - / -]
[Execute]
006 Execute:Y *ENG
[- / - / -]
[Execute]
020 Agitatiton Time *ENG
Sets agitation time for developer at TD sensor
initialization.
[0 to 200 / 30 / 1sec/step]
021 Initial TC *ENG
Sets initial toner concentration.
[1.0 to 15.0 / 7.0 / 0.1wt%/step]
031 Vt Target:K *ENG
Sets the target value for Vt at TD sensor
initialization.
[0.00 to 5.00 / 2.70 / 0.01V/step]
032 Vt Target:C *ENG
033 Vt Target:M *ENG
034 Vt Target:Y *ENG
041 Vt Target Corr:K *ENG
[0.00 to 2.55 / 0.00 / 0.01V/step]
042 Vt Target Corr:C *ENG
043 Vt Target Corr:M *ENG
044 Vt Target Corr:Y *ENG
3031 [TD Sens Init OK?]
3. SP Mode Tables
170