3431 [DrvTime: Setting]
001 Tmon:K *ENG
Sets supply on time per one supply at divided
supply control.
[50 to 1000 / 200 / 50msec/step]
002 Tmon:C *ENG
003 Tmon:M *ENG
004 Tmon:Y *ENG
011 Tmoff(min.):K *ENG
Sets the minimum supply time for toner supply
CL (or Mt).
[0 to 300 / 100 / 10msec/step]
012 Tmoff(min.):C *ENG
013 Tmoff(min.):M *ENG
014 Tmoff(min.):Y *ENG
3432 [DrvTime: Setting]
001 DriveTime(max) *ENG
Sets the maximum continuous supply time.
[0 to 1500 / 800 / 1msec/step]
3440 [Fixed Supply Mode]
001 Fixed Rate: K *ENG
Sets toner supply ratio for fixed supply mode.
[0 to 100 / 10 / 1%/step]
002 Fixed Rate: C *ENG
003 Fixed Rate: M *ENG
004 Fixed Rate: Y *ENG
3450 [Toner Supply PID: Setting]
001 Vt Proportion: K *ENG
Sets supply coeficient to supply toner
proportionate to Vt-Vtref at toner supply
control.
[0 to 2550 / 40 / 1/step]
002 Vt Proportion: C *ENG
003 Vt Proportion: M *ENG
004 Vt Proportion: Y *ENG
Main SP Tables-3