001 Std Speed: K *ENG
Displays the LD power determined by process
control.
[0 to 200 / - / 1%/step]
002 Std Speed: C *ENG
003 Std Speed: M *ENG
004 Std Speed: Y *ENG
021 Std Speed: K *ENG
Displays the LD power determined by process
control.
[0 to 200 / - / 1%/step]
022 Std Speed: C *ENG
023 Std Speed: M *ENG
024 Std Speed: Y *ENG
051 Std Speed: BW *ENG
071 Std Speed: BW *ENG
101 ProCon Corr: K *ENG
[0 to 200 / - / 1%/step]
102 ProCon Corr: C *ENG
103 ProCon Corr: M *ENG
104 ProCon Corr: Y *ENG
3619 [Dev DC Spd Correct:Set]
001 Coef Correct: Std Spd: K *ENG [0.50 to 1.50 / 1.00 /0.01step]
002 Coef Correct: Std Spd: C *ENG [0.50 to 1.50 / 1.00 /0.01step]
003 Coef Correct: Std Spd: M *ENG [0.50 to 1.50 / 1.00 /0.01step]
004 Coef Correct: Std Spd: Y *ENG [0.50 to 1.50 / 1.00 /0.01step]
005 Coef Correct: Low Spd: K *ENG [0.50 to 1.50 / 1.00 /0.01step]
006 Coef Correct: Low Spd: C *ENG [0.50 to 1.50 / 1.00 /0.01step]
007 Coef Correct: Low Spd: M *ENG [0.50 to 1.50 / 1.00 /0.01step]
008 Coef Correct: Low Spd: Y *ENG [0.50 to 1.50 / 1.00 /0.01step]
011 Offset: Std Spd: K *ENG [-128 to 127 / 0 / 10/step]
012 Offset: Std Spd: C *ENG [-128 to 127 / 0 / 10/step]
3. SP Mode Tables
212