022 Initial:C *ENG
Sets the initial value of developer gamma.
[0.50 to 2.55 / 0.80 / 0.01/step]
023 Initial:M *ENG
024 Initial:Y *ENG
031 Env Cor.(ON/OFF) *ENG
Sets on/off of developer gamma (environment
correction).
[0 or 1 / 1 / 1/step]
0:OFF, 1:ON
032 TC Cor.(ON/OFF) *ENG
Sets on/off of developer gamma (elapsed time
correction).
0 or 1 / 1 / 1/step]
0:OFF, 1:ON
041 Environ Corr:K *ENG Displays the environment correction of
developer gamma.
[-1.00 to 1.00 / - / 0.01mg/cm2/-kV/step]
042 Environ Corr:Col *ENG
051 TnrDensity Corr:K *ENG
Displays the toner density correction of
developer gamma.
[-1.00 to 1.00 / - / 0.01mg/cm2/-kV/step]
052 TnrDensity Corr:C *ENG
053 TnrDensity Corr:M *ENG
054 TnrDensity Corr:Y *ENG
061 TnrDensity:K *ENG
Displays the toner density calculated with TD
sensor output.
[0.0 to 25.5 / - / 0.1wt%/-kV/step]
062 TnrDensity:C *ENG
063 TnrDensity:M *ENG
064 TnrDensity:Y *ENG
071 Environ Corr1:Bk *ENG
Sets the table value for environment correction
of developer gamma.
[-1.00 to 1.00 / 0.00 / 0.01 mg/cm2/-kV /
step]
072 Environ Corr2:Bk *ENG
[-1.00 to 1.00 / 0.04 / 0.01mg/cm2/-kV/
step]
073 Environ Corr3:Bk *ENG
[-1.00 to 1.00 / 0.06 / 0.01mg/cm2/-kV/
step]
3. SP Mode Tables
220